2.03 CONCRETE MASONRY UNITS (CMU)<br />

1) Products: “Luster Seal WB 150,” Euclid Chemical Company<br />

2) Or approved equal.<br />

3) Gloss: Low sheen.<br />

b. Exterior Masonry Products:<br />

1) Hydrozo Enviroseal 20 (20% silane), BASF<br />

2) Aqua-Trete BSM 20<br />

3) Or approved equal.<br />

A. Provide all masonry shapes and sizes as indicated on the drawings. Units to conform to<br />

ASTM C-90, grade N-I. Maximum dimension for cells shall be 3". Block shall have uniform<br />

texture. Weight shall equal 125 pounds or greater and minimum strength of 2000 PSI based<br />

on net area. Weight shall be light weight (105 PCF).<br />

1. Portland Cement: ASTM C-150, Type I.<br />

2. Aggregates: Sand, ASTM C-144, except with not less than 5% (by weight) passing a<br />

No. 8 sieve, and with 95% to 100% (by weight) pass a 3/8" sieve.<br />

B. Provide masonry units of sufficient strength to obtain composite prism strengths of 1,500 psi<br />

compression for hollow units at 28 days.<br />

C. Block Types:<br />

1. Type “1”: 8” high by 16” long nominal, width to match brick wall, for use where not<br />

expose to view and where allowed by structural drawings.<br />

a. Color: Natural gray<br />

2.04 MORTAR AND GROUT MATERIALS<br />

A. Portland Cement: ASTM C-150, Type I or II. Provide natural color or white cement as<br />

required to produce required mortar color.<br />

B. Hydrated Lime: ASTM C-207, Type S.<br />

C. Aggregate for Mortar: ASTM C-144, except for joints less than 1/4 inch use aggregate graded<br />

with 100 percent passing the No. 16 sieve.<br />

D. Aggregate for Grout: ASTM C-404.<br />

E. Water: Potable.<br />

F. Minimum Allowable Strength: 2,600 psi at 28 days.<br />

2.05 MORTAR AND GROUT MIXES<br />

A. General: Do not add admixtures including coloring pigments, air-entraining agents,<br />

accelerators, retarders, water repellent agents, antifreeze compounds, or other admixtures,<br />

unless otherwise indicated.<br />

1. Do not use calcium chloride in mortar or grout.<br />

2. Refer to structural notes for additional requirements.<br />

3. Mortar Color: As selected by Architect. Colors will be selected to coordinate with the<br />

brick colors and may include more than one color.<br />

SEGO LILY ELEMENTARY SCHOOL CLASSROOM ADDITION MARCH 2, 2009<br />

UNIT MASONRY 04200-3