25. Facilities to automatically alter a call switch’s class of service by time of day and day<br />

of week as directed by the owner.<br />

26. It shall be possible to initiate Class of Service changes either manually or<br />

automatically on a per station basis using internal clock set.<br />

a. A minimum of four independent program memory sets shall be provided.<br />

b. Choice of time of service change and active memory set selected shall be<br />

completely programmable.<br />

b. Class of Service Changes shall be programmable by time of day and day of<br />

week.<br />

a. A minimum of 64 unique classes of service shall be available.<br />

27. Capability to assign speaker locations to any one or more of the zones for zone<br />

paging or time signal reception. This assignment to be a programmable function.<br />

28. Time signal tones shall be generated on a manual or automatic basis<br />

29. Emergency tones shall be distributed from designated Administrative Telephones.<br />

30. Power amplifiers shall meet all specifications exactly as specified herein,including<br />

power capacity and count.<br />

B. ADMINISTRATIVE TELEPHONES.<br />

1. All telephones will be IP phones provided by owner. Integrate with the updated<br />

Rauland intercom system.<br />

C. EMERGENCY/NORMAL CALL SWITCHES: Quam CIB-3<br />

1. Provide one (1) “Emergency” call switch that shall activate a distinctive “EMER” level<br />

call from a single button activation. Button shall be clearly marked “EMER” and shall<br />

route call to any one or more Administrative Telephones and/or Displays for quick<br />

and easy response from an Administrative Telephone. In accordance with the<br />

Americans with Disabilities Act (ADA), the “Emergency” call will provide a flashing<br />

call assurance LED confirming that the call has been placed in the system.<br />

2. Provide one (1) “Normal” call switch that shall activate a distinctive “NORM” level call<br />

from a single button activation. Button shall be clearly marked “NORM” and shall<br />

route call to any one or more Administrative Telephones and/or Displays for quick<br />

and easy response from an Administrative Telephone. In accordance with the<br />

Americans with Disabilities Act (ADA), the “Normal” call will provide a steady call<br />

assurance LED confirming that the call has been placed in the system.<br />

D. SWITCHPANEL:<br />

1. Program distribution shall have the capability to be upgraded to be controlled by both<br />

dial-up and switch panel selection for individual speakers or program distribution<br />

zones. Systems not providing for both switch panel AND dial-up program distribution<br />

will not be acceptable.<br />

2. When upgraded, speaker stations may be manually accessed by rack-mounted<br />

switch-panels specifically designed for individual and/or group station selection<br />

SEGO LILY ELEMENTARY SCHOOL CLASSROOM ADDITION March 2, 2009<br />

INTEGRATED ELECTRONIC COMMUNICATION NETWORK 16760-9