A. General: Limitations on usage as well as specific requirements that impact site utilization are<br />

indicated on the drawings and by other contract documents. In addition to these limitations<br />

and requirements administer allocation of available space so as to produce the best overall<br />

efficiency in performance of the total work of the project. Schedule deliveries so as to<br />

minimize space and time requirements for storage of materials and equipment on site.<br />

1.05 SUBMITTALS<br />

A. Coordination Drawings: Prepare and submit Coordination Drawings where close and careful<br />

coordination is required for installation of products and materials fabricated off-site by<br />

separate entities, and where limited space availability necessitates maximum utilization of<br />

space for efficient installation of different components.<br />

1. Show the interrelationship of components shown on separate Shop Drawings.<br />

2. Indicate required installation sequences.<br />

3. Comply with requirements contained in Section “Submittals.”<br />

4. Refer to Division 15 Section “Basic Mechanical Requirements” and Division 16<br />

Section “Electrical General Provisions” for specific coordination Drawings<br />

requirements for mechanical and electrical installations.<br />

PART 2 - PRODUCTS<br />

Not Used<br />

PART 3 - EXECUTION<br />

3.01 GENERAL INSTALLATION PROVISIONS<br />

A. Installer’s Inspection of Conditions: Require the Installer of each major unit of work to inspect<br />

the substrate to receive work and conditions under which the work is to be preformed. The<br />

Installer shall report all unsatisfactory conditions in writing to the Contractor. Do not proceed<br />

with the work until unsatisfactory conditions have been corrected in a manner acceptable to<br />

the Installer.<br />

B. Manufacturer’s Instructions: Comply with manufacturer’s installation instructions and<br />

recommendations, to the extent that those instructions and recommendations are more<br />

explicit or stringent than requirements contained in Contract Documents.<br />

C. Inspect each item of materials or equipment immediately prior to installation. Reject damaged<br />

or defective items.<br />

D. Provide attachment and connection devices and methods for securing work. Secure work true<br />

to line and level, and within recognized industry tolerances. Arrange joints in exposed work to<br />

obtain the best visual effect. Refer questionable visual-effect choices to the Architect for final<br />

decision. Allow for expansion and building movement.<br />

E. Install each unit-of-work during weather conditions and project status, which will ensure the<br />

best possible results in coordination with the entire work. Isolate each unit of work from<br />

incompatible work as necessary to prevent deterioration.<br />

F. Visual Effects: Provide uniform joint widths in exposed Work. Arrange joints in exposed Work<br />

to obtain the best visual effect. Refer questionable choices to the Architect for final decision.<br />

G. Recheck measurements and dimensions, before starting each installation.<br />

H. Coordinate temporary enclosures with required inspections and tests, to minimize the<br />

SEGO LILY ELEMENTARY SCHOOL CLASSROOM ADDITION MARCH 2, 2009<br />

PROJECT COORDINATION 01040 - 2

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!