. At door jambs<br />

c. At walls with tile finishes.<br />

B. Channels: 1-1/2", weighing 520 pounds per 1,000 lineal feet, 16 gage, painted.<br />

C. Furring channels: Roll-formed 25 gage electrogalvanized cold steel, "hat channels",<br />

approximately 2-5/8" wide at base, 7/8" deep.<br />

D. Ceiling runner channels: 1-1/2" cold-rolled steel, weighing 475 pounds per 1,000 lineal feet,<br />

rust inhibitive painted. Use same channel for partition reinforcing.<br />

E. Floor and ceiling runners: 25 gage electrogalvanized steel, "U" shaped sections, of sizes<br />

required to accommodate metal studs.<br />

F. Tie wire: 18 gage soft annealed galvanized steel wire.<br />

G. Hanger wire: 9 gage, galvanized annealed steel wire.<br />

H. Furring channels for 2" insulated wall (exterior) 25 gauge electro-galvanized cold steel.<br />

2.05 SOUND ATTENUATION BATT INSULATION<br />

A. Type: Unfaced glass fiber acoustical insulation complying with ASTM C 665, Type I.<br />

B. Size: 3-1/2 inches thick<br />

C. Surface Burning Characteristics, when tested in accordance with ASTM E 84:<br />

1. Maximum flame spread: 10<br />

2. Maximum smoke developed: 10<br />

D. Combustion Characteristics: Passes ASTM E 136.<br />

E. Fire Resistance Ratings: Passes ASTM E 119 as part of a complete fire tested wall assembly.<br />

F. Dimensional Stability: Linear Shrinkage less than 0.1%<br />

PART 3 - EXECUTION<br />

3.01 EXAMINATION<br />

A. Examine all subsurfaces to receive work and report, in writing to Architect, any detrimental<br />

conditions. Failure to observe this injunction constitutes a waiver to any subsequent claims to<br />

the contrary. Commencement of work will be construed as acceptance of all subsurfaces.<br />

3.02 INSTALLATION<br />

A. Suspension systems:<br />

1. All main runners shall be 1-1/2" runner channels at 48" o.c. suspend from structure by<br />

9 gage annealed wire, spaced at 36" o.c.<br />

2. Cross members shall be 7/8" hat channels at 16" o.c. Provide wall track where<br />

suspension system meets vertical surface.<br />

3. Deflection from loading of suspension system shall not exceed 1/360 of the span.<br />

4. When applicable comply with 1 hr. fire rating requirements.<br />

B. Framing:<br />

SEGO LILY ELEMENTARY SCHOOL CLASSROOM ADDITION MARCH 2, 2009<br />