04.03.2013 Views

RL78/D1A User's Manual: Hardware - Renesas

RL78/D1A User's Manual: Hardware - Renesas

RL78/D1A User's Manual: Hardware - Renesas

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Under development<br />

Preliminary document<br />

Specifications in this document are tentative and subject to change.<br />

<strong>RL78</strong>/<strong>D1A</strong> CHAPTER 6 TIMER ARRAY UNIT<br />

6.6.3 Applicable range of basic rules of combination operation function<br />

The rules of the combination operation function are applied in a channel group (a master channel and slave channels<br />

forming one combination operation function).<br />

If two or more channel groups that do not operate in combination are specified, the basic rules of the combination<br />

operation function in 6.6.2 Basic rules of combination operation function do not apply to the channel groups.<br />

Example<br />

CKm0<br />

CKm1<br />

CKm0<br />

TAU0<br />

Channel 0: Master<br />

Channel 1: Slave<br />

Channel 2: Slave<br />

Channel 3: Single-operation function<br />

Channel 4: Master<br />

Channel 5: Single-operation function<br />

Channel 6: Slave<br />

Channel 7: Single-operation function<br />

Channel group 1<br />

(combination-operation function)<br />

Channel group 2<br />

(combination-operation function)<br />

* The operation clock of channel group 1 may<br />

be different from that of channel group 2.<br />

* A channel that singly operates may be<br />

between channel group 1 and channel<br />

group 2.<br />

* A channel that singly operates may be<br />

between a master and a slave of channel<br />

group 2. Furthermore, the operating clock<br />

may be set separately.<br />

R01UH0317EJ0004 Rev. 0.04 402<br />

Feb. 22, 2013