04.03.2013 Views

RL78/D1A User's Manual: Hardware - Renesas

RL78/D1A User's Manual: Hardware - Renesas

RL78/D1A User's Manual: Hardware - Renesas

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Under development<br />

Preliminary document<br />

Specifications in this document are tentative and subject to change.<br />

<strong>RL78</strong>/<strong>D1A</strong> CHAPTER 14 CAN CONTROLLER<br />

(15) CAN module last in-pointer register (C0LIPT, C1LIPT)<br />

The C0LIPT, C1LIPT register indicates the number of the message buffer in which a data frame or a remote<br />

frame was last stored.<br />

Figure 14-41. Format of CAN Module Last In-pointer Register (C0LIPT, C1LIPT)<br />

Address: F05EEH (C0LIPT), F039EH (C1LIPT) After reset: Undefined R<br />

C0LIPT,<br />

C1LIPT<br />

7 6 5 4 3 2 1 0<br />

LIPT7 LIPT6 LIPT5 LIPT4 LIPT3 LIPT2 LIPT1 LIPT0<br />

LIPT7-LIPT0 Last In-Pointer Register (C0LIPT, C1LIPT)<br />

0 to 15 When the C0LIPT, C1LIPT register is read, the contents of the element indexed by the<br />

last in-pointer (LIPT) of the receive history list are read. These contents indicate the<br />

number of the message buffer in which a data frame or a remote frame was last stored.<br />

Remark The read value of the C0LIPT, C1LIPT register is undefined if a data frame or a remote<br />

frame has never been stored in the message buffer. If the RHPM bit of the C0RGPT,<br />

C1RGPT register is set to 1 after the CAN module has changed from the initialization<br />

mode to an operation mode, therefore, the read value of the C0LIPT, C1LIPT register<br />

is undefined.<br />

R01UH0317EJ0004 Rev. 0.04 865<br />

Feb. 22, 2013