<strong>RL78</strong>/<strong>D1A</strong> CHAPTER 14 CAN CONTROLLER<br />

Figure 14-76 shows the processing to skip resumption of transmitting a message that was stopped when transmission<br />

of an ABT message buffer was aborted.<br />

Figure 14-76. ABT Transmission Request Abort Processing (Normal Operation Mode with ABT)<br />

START<br />

Clear TRQ bit of message buffer<br />

undergoing transmission<br />

Clear ABTTRG bit<br />

ABTTRG = 0?<br />

Transmit abort<br />

Transmission start<br />

pointer clear?<br />

END<br />

Yes<br />

Yes<br />

Set ABTCLR bit<br />

Cautions 1. Do not set any transmission requests while ABT transmission abort processing is in<br />

progress.<br />

2. Make a CAN sleep mode/CAN stop mode request after ABTTRG is cleared (after ABT<br />

mode is stopped) following the procedure shown in Figure 14-75 or 14-76. When<br />

clearing a transmission request in an area other than the ABT area, follow the<br />

procedure shown in Figure 14-74.<br />

R01UH0317EJ0004 Rev. 0.04 932<br />

Feb. 22, 2013<br />

No<br />