Communication Manager Maintenance Object Repair Procedures<br />

MODEM-PT (Modem Pool Port)<br />

MO Name in Log Alarm Level Initial Command to Run Full Name of MO<br />

MODEM-PT MIN test port location Modem Pool Port<br />

The Modem Pool Port provides an interface for digital and analog data communication devices<br />

or ports connected to the PBX. It may be thought of as a PBX data communications “conversion<br />

resource” because it converts analog modem signals typically used in the telephone network<br />

into digital signals that are compatible with the internal PBX network and vice versa.<br />

There may be a number of these conversion resources available in the PBX, each assigned to<br />

an available Modem Pool Group. Only one conversion resource is used per data connection.<br />

The PBX software usually adds the conversion resource into a data connection if it determines<br />

that it is necessary for the call. Typical connections that include Modem Pool conversion<br />

resources include data calls from Analog Line or Central Office Trunk ports to any digital port or<br />

Digital Line or Trunk ports to any analog port. An example of a Data Module to Central Office<br />

Trunk connection using a Modem Pool conversion resource is shown in Figure 81: Typical<br />

Modem Pool Switched Connection with Integrated Pooled Modem. In the case where a local<br />

data call originates from an analog port normally used for voice service only and terminates on<br />

a digital port, a Data Origination access code must be dialed before the extension number for<br />

the Modem Pool conversion resource to be included in the connection.<br />

Each Modem Pool conversion resource contains two ports. One of these, an analog port, is<br />

connected (via the PBX network) to the analog line or trunk port that is the source of the modem<br />

signal. The second port is referred to as the digital port and is connected (again through the<br />

PBX network) to the digital line or trunk port associated with the Data Module in the connection.<br />

The analog modem signals enter the analog port of the conversion resource in standard Pulse<br />

Code Modulation (PCM) format, but are converted into Data Communications Protocol (DCP)<br />

format before going to the digital line or trunk in the connection.<br />

Integrated Modem Pools<br />

There are two primary types of Modem Pool conversion resources available: an Integrated<br />

Pooled Modem and a Combined Modem Pool. The integrated TN758 Pooled Modem circuit<br />

pack contains two independent 300- or 1200-bps conversion resources. Each conversion<br />

resource contains two interfaces to the PBX digital network: an analog port and a digital port.<br />

The analog port is connected through the PBX network to the analog line or trunk port<br />

containing the analog modem signals. The digital port connects through the PBX network to the<br />

digital line or trunk port in the call. Figure 81: Typical Modem Pool Switched Connection with<br />

Integrated Pooled Modem on page 1035 shows a typical end-to-end connection using a<br />

conversion resource on the integrated Pooled Modem circuit pack.<br />

1034 Maintenance <strong>Alarms</strong> for <strong>Avaya</strong> Communication Manager, Media Gateways and <strong>Server</strong>s