CO Port Diagnostic Test (#3)<br />

CO Port Diagnostic Test (#3)<br />

For ground start trunks, circuit pack or media module port relays are operated and checked to<br />

see if the port can detect and apply ground on the Tip lead. This test also verifies that there is no<br />

external ground on the Ring lead. In the absence of other failures, the circuit pack or media<br />

module should be replaced only if this test fails with the CO line disconnected.<br />

This test also checks the on-board programmable transmission circuits that allow the circuit<br />

pack or media module to support transmission characteristics of several different countries.<br />

This test runs on CO-TRK (Analog CO Trunk) and DIOD-TRK (DIOD Trunk).<br />

Table 378: CO Port Diagnostic Test (#3) 1 of 2<br />

Error<br />

Code<br />

1000<br />

1004<br />

Test<br />

Result<br />

Description / Recommendation<br />

ABORT Could not allocate system resources to run this test.<br />

1. Retry the command at 1-minute intervals up to 5 times.<br />

ABORT System resources required to run this test are not available.<br />

The port may be busy with a valid call.<br />

1. Enter display port location to determine the trunk group/<br />

member number of the port.<br />

2. Enter status trunk to determine the service state of the port. If<br />

the service state indicates that the port is in use, wait until the port is<br />

idle before retesting.<br />

3. Retry the command at 1-minute intervals up to 5 times.<br />

1005 ABORT Test is not valid for the present configuration. This error can be ignored.<br />

1018 ABORT Test has been disabled by administration. Determine why this test was<br />

disabled before enabling it.<br />

1. To enable the test, enter change trunk-group and<br />

enter y in the Maintenance Tests field on the Trunk Group form.<br />

2. Retry the command at 1-minute intervals up to 5 times.<br />

2000 ABORT Response from the test was not received within the time allowed.<br />

1. Retry the command at 1-minute intervals up to 5 times.<br />