Error Log Entries<br />

IPSV-CTL (IP <strong>Server</strong> Interface Control)<br />

Whenever an IPSI interchange takes place, an error is logged against IPSV-CTL with a code<br />

that conveys information about the cause of the interchange and which IPSI became active.<br />

See the following tables to identify areas of the Alarm Log to help find the source of the<br />

problem:<br />

● Encoding of Error Codes for Software Requested IPSI interchange<br />

● Aux Data Descriptions for Software-Requested Interchange,<br />

● Error codes for set ipserver-interface<br />

Table 244: Error Code Descriptions and Aux Data<br />

Error Code Description Aux Data<br />

3wxyz 1<br />

Software requested IPSI interchange / control change 2<br />

1. See Table 245 for encoding of the wxyz digits of the error code.<br />

2. Control change is moving the Archangel’s functionality to or from the IPSI.<br />

Error Codes for Software-Requested Interchanges<br />

See Table 246<br />

50000 Craft demand interchange of IPSI to A side See Table 246<br />

51000 Craft demand interchange of IPSI to B side See Table 246<br />

60000 Daily interchange of IPSI to standby failed 0<br />

61000 Daily interchange of IPSI back to previous active failed 0<br />

Table 245: Encoding of Error Codes for Software Requested IPSI interchange 1 of 2<br />

Field Variable Name Value Description<br />

w Active IPSI post<br />

action<br />

0 The A-side IPSI is active after the interchange.<br />

1 The B-side IPSI is active after the interchange.<br />

1 of 2<br />