Communication Manager Maintenance Object Repair Procedures<br />

Table 498: Expansion Interface Packet Interface Test (#589) 1 of 5<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

1033 ABORT The test cannot run because the EI circuit pack does not have a fiber link<br />

administered to it, there is not sufficient data to run the test, or because EI<br />

circuit packs on other port networks needed for this test are out of service.<br />

1. Enter list fiber-link and determine whether the EI circuit pack<br />

under test is an endpoint of one of the administered fiber links. If so,<br />

then proceed to step 2. If not, then this is considered to be a spare<br />

board, and the test should not be attempted on this EI circuit pack.<br />

2. Follow procedures for applicable configuration:<br />

Direct Connect:<br />

1. Enter list config for the cabinet and carrier where the neighbor EI<br />

circuit pack resides. If the results reveal that the board is not<br />

recognized by software, the board is out of service because of this<br />

condition. Perform the following steps:<br />

a. If this test is being executed on an EI circuit pack located in the PN,<br />

enter display errors and resolve any EXP-PN errors for the<br />

port network where the neighbor EI circuit pack resides. Re-run<br />

this test.<br />

b. If this test continues to abort with Error Code 1033, reset the DS1<br />

converter circuit pack, if so equipped, or the neighbor EI circuit<br />

pack. This will not be destructive since the circuit pack cannot be<br />

serving as the Expansion Archangel if it is not in service.<br />

2. Run Test #237 and check for EXP-INTF circuit pack Error Type 1281<br />

in the Error Log. If Error Type 1281 is present and/or Test #237 does<br />

not pass, see repair procedures for Expansion Interface Neighbor<br />

Query Test (#237).<br />

3. If Test #237 passes, reseat the EI circuit pack. This will not be<br />

destructive since the circuit pack cannot be serving as the Expansion<br />

Archangel if it is not in service.<br />

4. Rerun Test #237.<br />