3. Use the descriptions in Table 42 to interpret the report.<br />

Table 42: S8710 Temperature and voltage report<br />

Field Description<br />

ID An identification number automatically generated by the system.<br />

Type Power supply:<br />

● Intelligent—power regulating<br />

● Standard—other<br />

Fan: speeds include<br />

● Var Speed—variable speed<br />

● Basic Fan—fixed speed<br />

● Auto. Speed—automatic speed fan<br />

● Pwr Supply—power supply<br />

S8710 ENV <strong>Alarms</strong><br />

● Unknown<br />

Temperature: Basic Sensor—generic; ADM1022; Internal PS; Unknown<br />

Type<br />

Location The device location in the server.<br />

Status For power supplies and fans:<br />

● Normal—operating normally<br />

● Alarm—having a problem<br />

Redundant For all types: Yes, No, or NA<br />

Fan Speed Fans: percentage of full speed.<br />

● Unknown<br />

● Automatic—For Auto. Speed Fans, no speed state<br />

● Low—< 30%<br />

● Medium—30%–70%<br />

● High—> 70%, reporting state: High state<br />

● Normal—reporting state: Normal state<br />

● Off<br />

Current Temperature: current temperature of the device, in degrees Fahrenheit and<br />

Celsius.<br />

Threshold Temperature: above for which an alarm is generated, in degrees Fahrenheit<br />

and Celsius.<br />