Communication Manager Maintenance Object Repair Procedures<br />

Table 474: Signaling Link State Audit Test (#255) 1 of 2<br />

Error<br />

Code<br />

None<br />

or 0<br />

Test<br />

Result<br />

Description / Recommendation<br />

ABORT Internal system error.<br />

1. Retry the command up to 5 times at 1-minute intervals.<br />

1018 ABORT Test is disabled by administration.<br />

1. To enable the test, enter y in the Maintenance Tests field on the<br />

change trunk-group screen.<br />

1114 ABORT The signaling link is in a transitional state<br />

1. Retry the command up to 5 times at 1-minute intervals.<br />

1700 ABORT Rollabout video abort for PE-BCHL. The PRI terminal adapter<br />

associated with this PRI endpoint extension is detached from the circuit<br />

pack. This is a normal abort when the rollabout video feature is enabled.<br />

1. Either reconnect the disconnected PRI terminal adapter or disable<br />

the rollabout video feature on this circuit pack. To do the latter, enter<br />

change ds1 location and set the Alarm when PRI Endpoint<br />

Detached? field to y.<br />

4 FAIL There is a problem with the signaling channel.<br />

ATM-BCH:<br />

1. Look for errors or alarms against ATM-SGRP and ATM-DCH, and<br />

refer to ATM-SGRP (ATM Signaling Group) and ATM-DCH (ATM<br />

D-Channel Port) for the appropriate repair procedures.<br />

ISDN-TRK:<br />

1. If the Packet Control circuit pack is used, consult the procedures for<br />

ISDN-SGR (ISDN-PRI Signaling Group). Further information may<br />

also be obtained by consulting the procedures for the ISDN-PLK<br />

(ISDN-PRI Signaling Link Port).<br />

2. If the Packet Interface is used, consult the procedures for PKT-INT<br />

(Packet Interface)<br />

PE-BCH: There is a problem with the Signaling Channel and/or with the<br />

System Link.<br />

1. Consult procedures for ISDN-SGR (ISDN-PRI Signaling Group) and<br />

SYS-LINK (System Links). See also ISDN-PLK (ISDN-PRI Signaling<br />

Link Port) for useful information.<br />