Communication Manager Maintenance Object Repair Procedures<br />

PMS-LINK (Property Management System Link)<br />

MO Name in Log Alarm<br />

Level<br />

Property Management System (PMS) is a stand-alone computer system that environments<br />

such as hotels or hospitals use for services such as reservations, registration, messaging,<br />

housekeeping, night audit, billing, and inventory. The PMS Link provides a communications<br />

channel between the switch and the customer-owned PMS so that the PMS can interrogate the<br />

system for information related to the following features:<br />

● Message Waiting Notification<br />

● Controlled Restriction<br />

● Housekeeping Status<br />

● Check-in/Check-out<br />

Initial Command to Run Full Name of MO<br />

PMS-LINK MIN test pms-link long PMS Link<br />

WRN test pms-link<br />

● Room Change/Room Swap<br />

The PMS device connects to the system via a data module (PDM, MPDM, DTDM) connected to<br />

a port on a TN754 Digital Line circuit pack which is administered as a data extension. The PMS<br />

link to the processor is via a TN799 C-LAN port. For information about C-LAN connectivity, refer<br />

to CLAN-BD (Control LAN Circuit Pack).<br />

PMS Link maintenance provides a strategy for maintaining the link between the switch and a<br />

PMS device. The strategy includes a set of tests for periodic diagnosis, detection of errors<br />

during normal operation, actions for troubleshooting, and raising alarms for serious problems.<br />

PMS Link Maintenance uses a “try-and-wait” mechanism for maintaining the PMS Link. If a<br />

PMS Link is torn down due to an error, PMS Link Maintenance attempts to bring up the link<br />

immediately. If the Link Setup fails, PMS Link Maintenance will wait for five minutes before the<br />

next retry. If the number of retries reaches a threshold (12), a Minor alarm is raised for service<br />

attention.<br />

PMS Link Maintenance does not cover the maintenance of the elements composing the PMS<br />

physical link (the external PMS device, Data Module (PDM/MPDM/DTDM), Digital Line Port of a<br />

TN754 Digital Line circuit pack, ADU, or Data Line Port of TN726B Data Line circuit pack). If<br />

PMS Link Maintenance cannot restore the PMS Link, then the maintenance tests of these<br />

individual components of the PMS Link must be executed to diagnose faults. If test<br />

pms-link fails, no alarm will be generated.<br />

The list pms-down command lists every meaningful event to the PMS that occurred while<br />

the link between the switch and the PMS was down. For example, any room status codes<br />

entered by hotel housekeeping staff during a time of PMS outage would be shown in this report.<br />