Communication Manager Maintenance Object Repair Procedures<br />

If the test has failed within the last 5 minutes, there is a 15 second delay before the result is<br />

returned. This prevents a repeated sequence of this test from always reporting the same result.<br />

If the test passes and a FAIL has not occurred within the last five minutes, a PASS is returned<br />

immediately.<br />

This test is run on PKT-BUS (Packet Bus).<br />

Table 496: Packet Circuit Pack Audit Test (#573)<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

2500 ABORT Internal error.<br />

1. Retry the command at 1-minute intervals up to 5 times.<br />

1 FAIL One Packet circuit pack has reported packet bus-related inline errors within<br />

the last minute.<br />

2 FAIL More than one Packet circuit pack has reported packet bus-related inline<br />

errors within the last minute.<br />

PASS No Packet circuit packs have reported packet bus-related inline errors<br />

within the last minute. This indicates that the packet bus is healthy, or that a<br />

packet bus fault is transient or is being caused by a faulty Packet circuit<br />

pack. If this test passes, but there are other signs of a packet bus failure<br />

such as logged errors or alarms or other test failures, see Isolating and<br />

repairing packet-bus faults in Maintenance Procedures (03-300432).<br />

Board Type Check Test (#574)<br />

This test verifies that a Tone-Clock circuit pack administered with a Stratum-3 clock source has<br />

board code TN780.<br />

This test runs on the following maintenance objects:<br />

● TDM-CLK (TDM Bus Clock)<br />

● TONE-BD (Tone-Clock Circuit Pack)<br />

● TONE-PT (Tone Generator)<br />

1726 Maintenance <strong>Alarms</strong> for <strong>Avaya</strong> Communication Manager, Media Gateways and <strong>Server</strong>s

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!