TTR-LEV (TTR Level)<br />

c. Error Type 3: does not indicate a current error condition. It indicates that the number of<br />

GPTD ports in service was below the administered threshold, but is now equal to or greater<br />

than the threshold. These errors are typically generated during boot time or other<br />

transitional states when the ports are being brought into service.<br />

d. Error Type 4: the total number of GPTD ports currently in service is below the administered<br />

threshold. To clear the alarm, see Repair Procedure for TTR-LEV.<br />

e. Error Type 5: does not indicate a current error condition. It indicates that the number of Call<br />

Classifier ports (CLSFY-PT) service was below the administered threshold, but is now equal<br />

to or greater than the threshold. These errors are typically generated during boot time or<br />

other transitional states when the ports are being brought into service.<br />

f. Error Type 6: the total number of Call Classifier ports (CLSFY-PT) currently in service is<br />

below the administered threshold. To clear the alarm, see Repair Procedure for TTR-LEV.<br />

g. Error Type 7: there are currently no DTMR ports in service. To clear the alarm, see Repair<br />

Procedure for TTR-LEV.<br />

h. Error Type 8: there are currently no GPTD ports in service. To clear the alarm, see Repair<br />

Procedure for TTR-LEV.<br />

i. Error Type 9: there are currently no Call Classifier ports (CLSFY-PT) in service. To clear the<br />

alarm, see Repair Procedure for TTR-LEV.<br />

Communication Manager Release 5.0 Issue 4 January 2008 1379