09.12.2012 Views

Server Alarms - Avaya Support

Server Alarms - Avaya Support

Server Alarms - Avaya Support

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Communication Manager Maintenance Object Repair Procedures<br />

would be out of service due to the alarm. (There are five Tone Detectors on each of the<br />

two DSPs.) Other than the unlikely potential of running out of Tone Detector resources in<br />

the switch, there is no other effect when the board is reset.<br />

2. Test the board with test board location long.<br />

3. If the test still fails, replace the board.<br />

b. Error 257: The CLSFY-PT lost its translation. Testing the CLSFY-PT is sufficient to reload<br />

its translation. If testing the call classifier port does not clear the error, then the call classifier<br />

circuit pack containing the defective call classifier port should be replaced.<br />

c. Error 513: This error indicates the call classifier port is having problems detecting call<br />

classification tones or detecting and generating R2-MFC tones This is usually accompanied<br />

by failures of some incoming or outgoing calls. If this Error Type is persistently logged, then<br />

replace the call classifier circuit pack containing the defective CLSFY-PT.<br />

Demand test descriptions and error codes<br />

Investigate tests in the order presented. By clearing errors associated with the first test, errors<br />

generated from other tests may also be cleared. Click on the link to see the full description of<br />

the test, error codes, and recommended actions.<br />

Order of Investigation Short Test<br />

Sequence<br />

1. D = Destructive; ND = Nondestructive<br />

Long Test<br />

Sequence<br />

650 Maintenance <strong>Alarms</strong> for <strong>Avaya</strong> Communication Manager, Media Gateways and <strong>Server</strong>s<br />

D/ND 1<br />

Tone Detection Verification Test (#42) X X ND<br />

Tone Detector Audit/Update Test (#43) X X ND

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!