Table 484: PN Maintenance Circuit Pack Reset Test (#306) 2 of 3<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

1204 FAIL Response not received from the circuit pack.<br />

PN Maintenance Circuit Pack Reset Test (#306)<br />

1205 EI circuit pack could not reset the PN’s Maintenance circuit pack.<br />

For duplicated Port Network Connectivity:<br />

1. The standby EI circuit pack may be defective, preventing the<br />

active EI circuit pack from resetting the PN’s Maintenance circuit<br />

pack. Unplug the standby EI circuit pack, and try to reset the<br />

Maintenance circuit pack with test maint long. If Test #306<br />

passes, replace the standby EI circuit pack and attempt the reset<br />

test again. If Test #306 fails, replace the standby PN EI circuit<br />

pack.<br />

2. The active EI circuit pack may be defective and unable to reset<br />

the PN’s Maintenance circuit pack. Interchange the PNC with<br />

reset pnc interchange. Reset the Maintenance circuit pack<br />

again with test maintenance long. If the test passes, the<br />

problem is with the known standby EI circuit pack. Repeat Step 2<br />

to determine whether the standby EI circuit pack should be<br />

replaced.<br />

3. Replace the PN’s Maintenance circuit pack and run the test again.<br />

If the test passes, the problem is with the Maintenance circuit<br />

pack. Interchange the PNC with reset pnc interchange, and<br />

run the test again. The test should pass with both EI circuit packs<br />

being active.<br />

4. If the B carrier EI circuit pack is active, the ribbon cable<br />

connecting the Expansion Interface circuit pack and the PN’s<br />

Maintenance circuit pack may be defective. Check the ribbon<br />

cable to make sure it is connected properly and is not damaged.<br />

For unduplicated Port Network Connectivity:<br />

1. Replace the PN’s Maintenance circuit pack and run the test again.<br />

If it passes, the problem is with the Maintenance circuit pack.<br />

2. If the test fails, replace the EI circuit pack. If the tests passes, the<br />

problem is with the EI circuit pack.<br />

3. If the test still fails, the problem is with the serial link wired into the<br />

backplane of carrier A.<br />

2 of 3<br />

Communication Manager Release 5.0 Issue 4 January 2008 1703