This test runs on FIBER-LK (Fiber Link).<br />

Table 539: Fiber Link Reset Test (#768)<br />

Error<br />

Code<br />

Test<br />

Result<br />

Failure Audit (#777)<br />

Failure Audit (#777)<br />

This test queries the SNI(s) on the fiber link for any existing failures and unacknowledged<br />

cleared failure messages. Each failure generates an error and alarm entry against SNI-BD,<br />

SNI-PEER, or FIBER-LK. An unacknowledged cleared failure message is a message sent by<br />

the SNI circuit pack to software indicating that a previous failure is now gone, and the SNI circuit<br />

pack did not receive a message from software indicating that the failure message was received<br />

by software.<br />

If no failures are detected by the SNI circuit pack, this test will pass.<br />

If this test reports failures, the results of test fiber-link will display FAIL with no FAIL<br />

code. The error log must then be displayed using display errors with category PNC to view<br />

SNI-BD and FIBER-LK errors. Enter display errors with category PNC-PEER to view<br />

SNI-PEER errors.<br />

This test is not run for EI-to-EI fiber links. For EI-to-SNI fiber links, this test is run on the SNI<br />

circuit pack endpoint of the fiber link. For SNI-to-SNI fiber links, this test is run on both SNI<br />

circuit pack endpoints of the fiber link.<br />

This test runs on the following maintenance objects:<br />

● FIBER-LK (Fiber Link)<br />

● SNC-BD (Switch Node Clock Circuit Pack)<br />

● SNC-LINK (Switch Node Clock Link)<br />

● SNC-REF (Switch Node Clock Reference)<br />

● SNI-BD (SNI Circuit Pack)<br />

Description / Recommendation<br />

1703 ABORT Both fiber endpoints are in the hardware path for INLs to their respective<br />

switch node carriers and, therefore, cannot get a response from this test.<br />

1. Reset the individual fiber-link endpoints using reset board.<br />

2500 ABORT Internal system error<br />

1. Retry the command at 1-minute intervals up to 3 times.<br />

PASS The reset of both fiber endpoints successfully completed.<br />

Communication Manager Release 5.0 Issue 4 January 2008 1839