Signaling Link State Test (#1251)<br />

Signaling Link State Test (#1251)<br />

This test checks the current state of the signaling link. The test looks at the board-level<br />

translations, checks that the board is physically inserted, then gets the state of the D-channel<br />

and service state of the port.<br />

The test passes if the signaling link (D-channel) is connected and operating normally. The test<br />

fails if the board is not installed, the signaling link is disconnected, or if the port is out of service.<br />

The test aborts otherwise.<br />

This test runs on TBRI-TRK (ISDN Trunk-Side BRI Channel).<br />

Table 589: Signaling Link State Test (#1251)<br />

Error<br />

Code<br />

Test<br />

Result<br />

ATM Board Reset (#1256)<br />

This test is destructive.<br />

Description / Recommendation<br />

ABORT Internal system error<br />

1. Retry the command at 1-minute intervals up to 5 times.<br />

1018 ABORT The test is disabled.<br />

1. Enable the test by entering enable test 1251.<br />

1114 ABORT The signaling link is in a transitional state.<br />

1. Retry the command at 1-minute intervals up to 5 times.<br />

8 FAIL The signaling link is down.<br />

1. Consult the procedures for TBRI-TRK (ISDN Trunk-Side BRI<br />

Channel).<br />

9 FAIL The port is out of service.<br />

1. Consult the procedures for TBRI-PT (ISDN Trunk-Side BRI Port).<br />

PASS The signaling link is connected and operating normally.<br />

Communication Manager Release 5.0 Issue 4 January 2008 1953