Error log entries and recommended actions<br />

Table 336: STRAT-3 Error Log Entries<br />

Error<br />

Type<br />

Aux<br />

Data<br />

Associated Test Alarm<br />

Level<br />

On/Off<br />

Board<br />

STRAT-3 (Stratum-3 Clock)<br />

Recommended Action<br />

0 (a) 0 Any Any Any test synchronization r 4<br />

1 (b) Any Stratum-3 Clock Alarm<br />

Query (#649)<br />

MIN OFF test synchronization r 4<br />

18 (c) 0 disable sync WRN OFF enable sync<br />

257 (d) Any Stratum-3 Clock Alarm<br />

Query (#649)<br />

513 (e) Any Stratum-3 Clock Alarm<br />

Query (#649<br />

769 (f) Any Stratum-3 Clock Alarm<br />

Query (#649)<br />

1025 (g) Any Stratum-3 Clock Alarm<br />

Query (#649)<br />

1281 (h) Any Stratum-3 Clock Alarm<br />

Query (#649)<br />

MIN OFF test synchronization r 4<br />

MIN ON test synchronization r 4<br />

MIN ON test synchronization r 4<br />

MIN<br />

MAJ ()<br />

MIN<br />

MAJ ()<br />

1537 (i) MIN<br />

MAJ ()<br />

1793 (j) MIN<br />

MAJ ()<br />

ON test synchronization r 4<br />

ON test synchronization r 4<br />

Notes:<br />

a. Error Type 0: Run the short test sequence first. If every test passes, run the long test<br />

sequence. Refer to each test’s description, and follow its procedures.<br />

b. Error Type 1: this Error Type corresponds to FAIL code 1 of the Stratum-3 Clock Alarm<br />

Query (#649)): Either reference A failed or the CI card A failed.<br />

c. Error Type 18: Synchronization Maintenance was disabled with disable<br />

synchronization-switch.<br />

1. Enter enable synchronization-switch to enable Synchronization Maintenance<br />

reference switching and to resolve this alarm.<br />

d. Error Type 257: this Error Type corresponds to FAIL code 2 of the Stratum-3 Clock Alarm<br />

Query (#649): one power supply failed.<br />

e. Error Type 513: this Error Type corresponds to FAIL code 4 of the Stratum-3 Clock Alarm<br />

Query (#649): one clock unit failed.<br />