Denial Events<br />

Table 57: Call Process denial events (1225 - 1899) 6 of 35<br />

Event<br />

Type<br />

Event Description, as it<br />

appears on the event log<br />

Explanation Event<br />

Data 1<br />

1351 More digits expected Appending "#" to end of digit buffer. All digits<br />

have been processed for an Adjunct Switch<br />

Application Interface (ASAI) originated call, but<br />

more digits are expected to be collected.<br />

1352 Port ntwk numbr too large Facility access test specified a port network<br />

number greater than the maximum allowed.<br />

1353 Cabinet number too large Malicious call trace specified a cabinet number<br />

greater than the maximum allowed.<br />

1354 SSC dialed ext's uid fail Station Security Code (SSC) digit processing.<br />

The dialed extension’s User ID has lost its<br />

association with the extension number.<br />

1355 Auth code reqired. (ASAI) Call requires an authorization code. Call is an<br />

Adjunct Switch Application Interface (ASAI)<br />

phantom call. Not allowed.<br />

1356 ASAI SCC VDN destination The first leg of an Adjunct Switch Application<br />

Interface (ASAI) Switch Classified Call (SCC) has<br />

Vector Directory Number as destination.<br />

1357 LAGT COR/COR restriction There is a COR-to-COR restriction between the<br />

originating logical agent and the terminating<br />

facility.<br />

1358 ASAI SCC term loginID First leg of Adjunct Switch Application Interface<br />

(ASAI) Switch Classified Call (SCC) attempting to<br />

terminate to logical agent loginID. Not allowed.<br />

1359 LoginID extensn qry fail Failure to determine if the loginID extension used<br />

for the Direct Agent call is associated with a<br />

logged-in agent.<br />

1360 ASAI SCC term loginID First leg of Adjunct Switch Application Interface<br />

(ASAI) Switch Classified Call (SCC) attempting to<br />

terminate to logical agent loginID. Not allowed.<br />

1361 Page data call preindictd Paging is denied if data call preindication was<br />

activated.<br />

1362 FAC follows priority FAC Priority feature activation code should not be<br />

followed by other feature activation codes. (auth)<br />

1363 SIP Agent logins max’d Maximum number of simultaneous SIP EAS<br />

Agent logins exceeded.<br />

1364 Not priority destination Priority feature activation code should not be<br />

followed by other feature activation codes. (other)<br />

1365 More digits needed to rte Adjunct Switch Application Interface (ASAI) call.<br />

Need more digits to route on. There are no digits<br />

left to use in the preprocessing buffer, and no<br />

more digits are expected.<br />

1366 BCC incompatibility Auth code entered. Bearer Capability Class<br />

(BCC) incompatibility.<br />

1367 BCC incompatibility No auth code entered. Bearer Capability Class<br />

(BCC) incompatibility.<br />

220 Maintenance <strong>Alarms</strong> for <strong>Avaya</strong> Communication Manager, Media Gateways and <strong>Server</strong>s<br />

Event Data 2<br />

6 of 35