Communication Manager Maintenance Object Repair Procedures<br />

The test aborts if the system resources such as TDM time slots and Tone Generator are not<br />

available.<br />

This test applies to TN2305 and TN2306 ATM-EIs, both active and standby. It runs on ATM-EI<br />

(Expansion Interface Circuit Pack) and ATM-TRK (Circuit Emulation Service Circuit Pack).<br />

Table 604: ATM Board DSP Test (#1293) 1 of 2<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

1002 ABORT The system could not allocate time slots for the test. The system may be<br />

under heavy traffic conditions, or it may have time slots out-of-service<br />

due to TDM-BUS errors. A system is considered under heavy traffic when<br />

the Call Processing Occupancy is greater than 50% or when the System<br />

Management and the Call Processing Occupancies together exceed<br />

65%.<br />

1. Enter status health to view the occupancy measurements.<br />

2. Enter display errors and resolve any TDM-BUS (TDM Bus)<br />

errors.<br />

3. If the system has no TDM-BUS errors and is not handling heavy<br />

traffic, retry the command at 1-minute intervals up to 5 times.<br />

1003 ABORT The system could not allocate a tone receiver for the test. The system<br />

may be oversized for the number of Tone Detectors present, or some<br />

Tone Detectors may be out of service.<br />

1. Enter list measurements tone-receiver to see information<br />

regarding the system’s tone receivers.<br />

2. Resolve any TTR-LEV (TTR Level) errors.<br />

3. Resolve any TONE-PT (Tone Generator) errors.<br />

4. Retry the command at 1-minute intervals up to 5 times.<br />

1962 ABORT Every DSP is busy. This is a very unlikely event.<br />

1. Retry the command at 1-minute intervals up to 3 times.<br />

2000 ABORT Response to the test was not received within the allowed time.<br />

1. If the board is in standby, reset the board and run the test again.<br />

2. Check the Error Log for Error Type 1281 (bad DSP). If Error Type<br />

1281 is not logged against this board, run the DSP test again.<br />

3. If the error persists, escalate.<br />