Communication Manager Maintenance Object Repair Procedures<br />

Demand test descriptions and error codes<br />

There are no demand tests for EXP-PN. Two reset tests, PN Cold Restart Test (#955) and PN<br />

Warm Restart Test (#956) can be executed to reset a PN.<br />

The PN Warm Restart Test (#956) restarts a PN that has not been taken out of service. It is the<br />

least severe of the PN restart levels and is used in an attempt to preserve the state of the<br />

system as much as possible, thereby reducing user impact. The command for this type of<br />

restart is reset port-network P level 1 where P is the port network number.<br />

The PN Cold Restart Test (#955) is used as a recovery mechanism for a PN that has been<br />

taken out of service. It is executed as a result of PN recovery escalation when a Warm Restart<br />

is not possible, or as a result of a system technician demanded PN restart. Once a PN has gone<br />

out of service, a PN Cold Restart is required to bring it back into service. This is the most severe<br />

of the PN restarts, and users will experience a service outage. The command for this type of<br />

restart is reset port-network P level 2 where P is the port network number.<br />