Expansion Interface Lock Query Test (#304)<br />

Expansion Interface Lock Query Test (#304)<br />

The Expansion Interface Lock Query Test queries the ATM EI circuit pack for its status<br />

concerning a lock to the backplane system clock. The test passes if the response is "in lock".<br />

The test fails if the response is "out of lock". This test runs on ATM-EI (Expansion Interface<br />

Circuit Pack).<br />

Table 483: Expansion Interface Lock Query Test (#304) 1 of 2<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

2000 ABORT Response from the test was not received within the time allowed.<br />

1. Retry the command at 1-minute intervals up to 3 times.<br />

2100 ABORT Could not allocate the necessary system resources to run this test.<br />

1. Retry the command at 1-minute intervals up to 3 times.<br />

2500 ABORT Internal system error<br />

1. Retry the command at 1-minute intervals up to 3 times.<br />

FAIL A PN’s unduplicated ATM-EI circuit pack responded incorrectly, or a PN’s<br />

active ATM-EI circuit pack could not communicate with the PN’s circuit<br />

packs.<br />

1. If the PN’s active ATM-EI circuit pack is failing and duplicated PNC is<br />

enabled:<br />

a. Enter reset PNC interchange to switch to the standby PNC.<br />

b. Repeat the short test sequence.<br />

c. If test continues to fail, enter reset board location to reset<br />

the ATM-EI circuit pack.<br />

2. If the PN’s unduplicated ATM-EI circuit pack is failing:<br />

a. Enter display errors and display alarms, and follow the<br />

associated repair procedures for TDM-CLK, TONE-BD, or SYNC<br />

alarms/errors.<br />

b. Repeat the short test sequence.<br />

c. If test continues to fail, replace the circuit pack or transceiver.<br />

PASS Communication to the ATM-EI circuit pack is functioning correctly.<br />

1 of 2<br />

Communication Manager Release 5.0 Issue 4 January 2008 1701