Note: The<br />

Note: Make<br />

EXP-INTF (Expansion Interface Circuit Pack)<br />

Note:<br />

fiber connected to the transmit side of the lightwave transceiver on one EI<br />

circuit pack should be connected to the receive side of the lightwave transceiver<br />

on the circuit pack on the opposite end of the fiber.<br />

3. Using a fiber jumper cable, interconnect the transmit and receive jacks of the lightwave<br />

transceiver as shown in Figure 65: Interconnection of Lightwave Transceiver Transmit/<br />

Receive Jacks.<br />

Note:<br />

sure that the total length of the fiber jumper cable does not exceed the<br />

maximum length recommended for the fiber link connections between cabinets.<br />

Using cable lengths not within connectivity guidelines can adversely affect test<br />

results.<br />

4. Go to the front of the cabinet and inspect the amber LED.<br />

● If the amber LED flashes on at a rate of once per second, the (EI or SNI) circuit pack or<br />

transceiver should be replaced.<br />

● If the amber LED flashes on at a rate of five times per second, the circuit pack (EI or SNI)<br />

or the lightwave transceiver may need replacement. This condition may also be due to a<br />

faulty system clock on the network containing this EI circuit pack.<br />

● If the amber LED is not blinking, this circuit pack (EI or SNI) and the lightwave transceiver<br />

are functioning properly.<br />

5. Replace faulty components and reconnect the original fiber. Be sure to reconnect the fibers<br />

properly as noted in step 3. If there is a problem with the PN after re-connecting the fiber,<br />

and the PN is connected to a Center Stage Switch, run the Configuration Audit via test<br />

board on the SNI circuit pack to which the intervening fiber is connected. See the SNI-BD<br />

section for instructions on interpreting results.<br />

6. Release EI circuit pack or SNI circuit pack with release board location.<br />