Communication Manager Maintenance Object Repair Procedures<br />

Call State Audit Test (#257)<br />

This test audits internal call state data by querying the far-end terminal adapter as to the ISDN<br />

state of the call. This can be helpful when trying to clear a hung call. If a call is active on the port,<br />

the switches on both sides of the connection should agree on the ISDN state of the call as<br />

defined in the ISDN Protocol Specification. If the internal call state data on the near-end switch<br />

is different than that of the far-end terminal adapter, the call will be torn down.<br />

The ISDN specification allows up to 2 minutes for a reply. If a reply is not received within the 2<br />

minute window, the test logs a protocol time-out violation against the associated signaling<br />

channel (Error Type 1 for ATM-DCH, ISDN-PLK).<br />

his test is run on the following maintenance objects:<br />

● ATM-BCH (ATM B-Channel Trunk)<br />

● ISDN-TRK (DS1 ISDN Trunk)<br />

● PE-BCHL (PRI Endpoint Port)<br />

● TBRI-TRK (ISDN Trunk-Side BRI Channel)<br />

Table 476: Call State Audit Test (#257) 1 of 2<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

1018 ABORT Test is disabled<br />

1. Enable the test by entering y in the Maintenance Tests field on the<br />

change trunk-group screen.<br />

1019 ABORT Audit already in progress<br />

1. Wait 2 minutes, and try again.<br />

1113 ABORT Signaling link failed<br />

ATM-BCH, ISDN-TRK, PE-BCHL:<br />

1. Check the results of Signaling Link State Audit Test (#255).<br />

TBRI-TRK:<br />

1. Check the results of Signaling Link State Test (#1251).<br />

1114 ABORT Signaling link in transitional state<br />

1. Retry the command up to 5 times at 1-minute intervals.<br />