Communication Manager Maintenance Object Repair Procedures<br />

Table 525: Layer 2 Status Query Test (#647) 1 of 2<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

1132 ABORT The port location for the primary D-channel is not known. This condition<br />

should not be possible since an administered circuit pack or media<br />

module must be specified when a Signaling Group is administered.<br />

1. Retry the command at 1-minute intervals up to 5 times.<br />

1134 ABORT The associated circuit pack or media module is not administered. This<br />

condition should not be possible since an administered circuit pack or<br />

media module must be specified when a Signaling Group is<br />

administered.<br />

1. Retry the command at 1-minute intervals up to 3 times.<br />

2500 ABORT Internal system error:<br />

1. Retry the command at 1-minute intervals up to 5 times.<br />

1 FAIL Layer 2 of the primary signaling channel is down:<br />

1. Examine the results of the Primary Signaling Link Hardware Check<br />

(#636), and follow recommendations provided there.<br />

2. If Test #636 passes, the Layer 2 Query test may still fail if the<br />

signaling channel at the far end has not been administered correctly<br />

or if the signaling channel has been busied out.<br />

a. Verify that the Primary Signaling Channel (D-channel) at the far<br />

end has been administered correctly.<br />

b. Verify that the port used for the Primary D-channel has not been<br />

busied out at the far end.<br />

2 FAIL Layer 2 of the secondary signaling channel is down.<br />

1. Examine the results of the Secondary Signaling Link Hardware<br />

Check (#639), and follow recommendations provided there.<br />

2. If tests #639 passes, the Layer 2 Query test may still fail if the<br />

signaling channel at the far end has not been administered correctly<br />

or if the signaling channel has been busied out.<br />

a. Verify that the Secondary Signaling Channel (D-channel) at the far<br />

end has been administered correctly.<br />

b. Verify that the port used for the Secondary D-channel has not<br />

been busied out at the far end.<br />

1786 Maintenance <strong>Alarms</strong> for <strong>Avaya</strong> Communication Manager, Media Gateways and <strong>Server</strong>s<br />

1 of 2