Communication Manager Maintenance Object Repair Procedures<br />

DIG-IP-S (Digital IP Station)<br />

The DIG-IP-S MO represents Softphone and <strong>Avaya</strong> 46XX phones. Softphone has some DCP<br />

maintenance capability in the form of audits, updates, error log entries, and tests. <strong>Avaya</strong> 46XX<br />

IP phones communicate to the switch via an IP LAN and emulate DCP signaling carried over<br />

TCP.<br />

The IP phone is not attached to a port board. Insertion of the phone is driven by successful<br />

registration of the endpoint, not by board insertion. It is maintained via a set of explicit TCP/IP<br />

ping requests and errors reported by the User Manager software, which terminates the H.323<br />

signaling portion of each endpoint. The MO follows standard maintenance methodology and<br />

supports test, busyout, release and status commands.<br />

A registered extension has a port number or ID in the form of SNNNNN, where N is a digit from<br />

0–9. This ID indicates that the extension is a virtual port and a station.<br />

Note: A<br />

MO Name in Log Alarm Level Initial Command to Run Full Name of MO<br />

DIG-IP-S WRN test station extension Digital IP Station<br />

Note:<br />

port number or ID of SNNNNN does not necessarily indicate that the extension<br />

is registered. A registered extension retains the SNNNNN port number or ID,<br />

even if the extension later unregisters.<br />

Error log entries and recommended actions<br />

Table 179: DIG-IP-S Error Log Entries 1 of 2<br />

Error<br />

Type<br />

Aux<br />

Data<br />

Associated Test Alarm<br />

Level<br />

On/Off<br />

Board<br />

Recommended Action<br />

0 0 Any Any test station extension<br />

1 (a) Registration Status<br />

Inquiry (#1372)<br />

18 (b) 0 busyout port |<br />

station<br />

257 (c) Signaling Path PING test<br />

(#1373)<br />

513 (d) Any Digital Station Audits Test<br />

(#17)<br />

WRN OFF<br />

WRN OFF release port | station<br />

WRN OFF<br />

WRN OFF test port | station<br />

688 Maintenance <strong>Alarms</strong> for <strong>Avaya</strong> Communication Manager, Media Gateways and <strong>Server</strong>s<br />