Table 407: Analog Line Ringer Update Test (#62) 2 of 2<br />

Error<br />

Code<br />

Test<br />

Result<br />

0 NO<br />

BOARD<br />

Description / Recommendation<br />

Tie Trunk Seizure Test (#73)<br />

Tie Trunk Seizure Test (#73)<br />

PASS Analog Line Ringer Update passed<br />

1. If complaints still exist, investigate using other circuit pack tests on<br />

this circuit pack, and by examining the terminal, wiring, and<br />

connections.<br />

See NO BOARD for the recommended repair procedures.<br />

2 of 2<br />

This test performs a seizure test on an analog tie trunk. The tie trunk must be outgoing, and be<br />

wink-start, delay-dial, continuous-seize-ack, discontinuous-seize-ack trunks, or TGU/E/I. This<br />

test activates the M lead and checks for a response from the far end within 10 seconds.<br />

The test seizes a trunk and outpulses a pause. The port reports the result of the seizure. This<br />

test can be disabled using the Test field on the Trunk Group Administration screen.<br />

This test aborts on ports administered as access endpoints.<br />

This test runs on TIE-TRK (Analog Tie Trunk).<br />

Table 408: Tie Trunk Seizure Test (#73) 1 of 3<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

ABORT Could not allocate the necessary system resources to run this test.<br />

1. Retry the command at 1-minute intervals up to 5 times.<br />

1 of 3<br />

Communication Manager Release 5.0 Issue 4 January 2008 1533