Communication Manager Maintenance Object Repair Procedures<br />

BRI Port Local LAN Looparound Test (#618)<br />

This test is destructive.<br />

This test checks the connectivity of a BRI port across the LAN Bus and executes only if the port<br />

is out-of-service. The test aborts if calls associated with the port are in-progress. Failures of this<br />

test indicate either on-board faults associated with the port hardware on the circuit pack or<br />

problems with the LAN Bus.<br />

This test runs on the following maintenance objects:<br />

● ASAI-PT (ASAI Port)<br />

● BRI-PORT (ISDN-BRI Port)<br />

● TBRI-PT (ISDN Trunk-Side BRI Port)<br />

Table 508: BRI Port Local LAN Looparound Test (#618) 1 of 2<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

1015 ABORT The port is not out-of-service.<br />

1. Enter status bri-port location to determine what stations or<br />

adjuncts are on this port.<br />

2. Enter status station extension to determine whether the<br />

station or adjunct is in use.<br />

3. If the port is in use, wait until it is idle, then busyout the port with<br />

busyout port location to place it in the out-of-service state.<br />

Repeat this test.<br />

WARNING: Since<br />

! WARNING:<br />

the “busyout” command is destructive, execution of<br />

this command prior to the port being idle causes every call<br />

associated with BRI endpoints and every transaction<br />

associated with ASAI or <strong>Avaya</strong> adjuncts on the port to be<br />

torn down. Note that 3rd-party calls established by an<br />

ASAI or <strong>Avaya</strong> adjunct remain connected even though the<br />

port is taken out-of-service.<br />

1139 ABORT The packet bus in the port network is out-of-service.<br />

1. Follow the repair procedures for the PKT-BUS (Packet Bus).<br />

2. Enter test port long location and view the results of the BRI<br />

Port Local LAN Looparound Test #618 to verify the repair.<br />