Communication Manager Maintenance Object Repair Procedures<br />

Table 342: SYNC Error Log Entries 2 of 2<br />

Error Type Aux<br />

Data<br />

Associated Test Alarm<br />

Level<br />

1 (b)(i) WRN<br />

MIN (g)<br />

Notes:<br />

a. Error Type 0: run the short test sequence first. If every test passes, run the long test<br />

sequence. Refer to each test’s description, and follow its procedures.<br />

b. Error Type 1: run the short test sequence first. If every test passes, run the long test<br />

sequence. Refer to each test’s description, and follow its procedures.<br />

This error indicates a problem with the primary DS1 reference. It is cleared when the<br />

primary reference is restored. To find the problem’s source:<br />

1. Enter list configuration board location to check if the primary DS1 Interface<br />

circuit pack is inserted in the carrier.<br />

2. Verify that the administered primary reference matches the DS1 reference from the<br />

network synchronization plan.<br />

3. Enter test board location long to test the primary DS1 Interface circuit pack.<br />

Check the Error Log for DS1-BD or UDS1-BD errors and see DS1-BD (DS1 Interface<br />

Circuit Pack) or UDS1-BD (UDS1 Interface Circuit Pack) to resolve errors associated<br />

with the primary DS1 (DS1 or UDS1) interface circuit pack.<br />

If the only errors against DS1-BD or UDS1-BD are slip errors, follow the procedures<br />

described in the previous troubleshooting section. If no errors are listed in the Error Log<br />

for the primary DS1 Interface circuit pack, continue with the following steps.<br />

1276 Maintenance <strong>Alarms</strong> for <strong>Avaya</strong> Communication Manager, Media Gateways and <strong>Server</strong>s<br />

OFF<br />

18 (c) 0 disable sync WRN OFF enable sync<br />

257 (d)(i) WRN<br />

MIN (i)(g)<br />

513 (e)(i) WRN<br />

MAJ (i)(g)<br />

OFF<br />

OFF<br />

769 (f) MAJ OFF<br />

1793 (g) 1 0–50 MAJ OFF<br />

2049 (h) 0 WRN OFF<br />

1. It can take up to 1 hour for these alarms to clear.<br />

On/Off<br />

Board<br />

Recommended Action<br />

2 of 2