Communication Manager Maintenance Object Repair Procedures<br />

Table 133: Error type 1281 Aux Data and repair procedures 2 of 3<br />

Aux<br />

Data<br />

Alarm<br />

Description<br />

19 Multiplexer<br />

Section<br />

Remote Defect<br />

Indicator:<br />

MS_RDI<br />

20 Loss of pointer:<br />

LOP<br />

21 Path Signal<br />

Error (PSL)<br />

(STM1/<br />

SONET)<br />

22 High-level Path<br />

Alarm<br />

Indication<br />

Signal:<br />

HP_AIS<br />

Repair procedure<br />

The far end is detecting a major problem with the signal that this<br />

board is transmitting.<br />

1. Make sure the ATM switch port (or a MUX port, if present<br />

between ATM switch and the ATM-EI board) is the same as the<br />

ATM-EI circuit pack’s cable interface.<br />

2. Run test board location.<br />

3. If Test #1259 fails with Error Code 19, connect a fiber<br />

back-to-back in a looped mode (one strand of fiber connecting<br />

the transmit transceiver to the receive transceiver of the board)<br />

and see if the amber LED flash goes away.<br />

4. If it does the problem is off-board.<br />

5. If the amber LED continues to flash, replace the circuit pack; if<br />

the error persists, escalate the problem.<br />

ATM framer chip is unable to access the payload part of the signal.<br />

1. Reset the board (reset board location).<br />

2. If the error persists replace the board.<br />

The incoming signal payload is not set up for transmission of ATM<br />

data.<br />

1. Make sure the ATM switch port (or a MUX port, if present<br />

between ATM switch and the ATM-EI board) is the same as the<br />

ATM-EI circuit pack’s cable interface.<br />

The payload is invalid.<br />

1. Make sure the ATM switch port (or a MUX port, if present<br />

between ATM switch and the ATM-EI board) is the same as the<br />

ATM-EI circuit pack’s cable interface.<br />

2. Run test board location.<br />

3. If Test #1259 fails with Error Code 22, connect a fiber<br />

back-to-back in a looped mode (one strand of fiber connecting<br />

the transmit transceiver to the receive transceiver of the board)<br />

and see if the amber LED flash goes away.<br />

4. If it does the problem is off-board.<br />

5. If the amber LED continues to flash, replace the circuit pack.<br />