DS1C-BD (DS1 Converter Circuit Pack)<br />

Table 191: Upgrading TN574 DS1 Converter Circuit Packs in a fiber-link to TN1654s —<br />

Duplicated PNC 2 of 2<br />

Steps Comments<br />

Enter change system-parameters<br />

duplication. Enter y in Enable<br />

Operation of PNC Duplication<br />

field.<br />

Enter add fiber-link fiber# to<br />

re-add the fiber-link using TN1654 DS1<br />

converter circuit packs.<br />

Enter test alarms long clear for<br />

category exp-intf.<br />

Wait 5 minutes for SNI-BD, SNI-PEER,<br />

FIBER-LK and DS1C-BD alarms to<br />

clear, or enter clear<br />

firmware-counters a-pnc |<br />

b-pnc.<br />

Enable PNC duplication.<br />

fiber# represents the fiber-link number<br />

associated with the TN574 DS1 converter<br />

complexes that are being upgraded to TN1654<br />

DS1 converter complexes.<br />

Enter status pnc. If either PNC’s state of health is not “functional”,<br />

consult the PNC-DUP section of the Maintenance<br />

Manual.<br />

2 of 2<br />

Communication Manager Release 5.0 Issue 4 January 2008 757