Communication Manager Maintenance Object Repair Procedures<br />

Table 441: TDM Bus Clock Circuit Status Inquiry Test (#148) 3 of 3<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

65 FAIL The Processor/Tone-clock is currently not able to lock on to the current<br />

synchronization reference. If this tone-clock is in the master port<br />

networK:<br />

1. Examine the error log for any DS1-BD, SYNC or other TDM-CLK<br />

errors and resolve as applicable.<br />

2. Run this test again using test tone-clock location.<br />

3. Examine the DS1 measurements to determine whether the facility is<br />

healthy.<br />

4. Administer a new synchronization reference.<br />

5. Replace the DS1 board currently supplying the reference.<br />

If this tone-clock is in the slave port network:<br />

6. Examine the error log for any SYNC, EXP-INTF, or TDM-CLK<br />

errors.<br />

7. Run this test again with test tone-clock location.<br />

66 FAIL There is an on-board failure of TDM clock hardware.<br />

1. Enter test tone location long to resolve the problem. The<br />

long test resets the board and is required to reload on-board RAM<br />

associated with the TN2182’s DSPs. The effect is that tone<br />

detectors are taken out of service momentarily and tones are<br />

removed from the TDM bus for about 10 seconds. This means that<br />

no dial tone or touch tones are available during this interval. It<br />

probably will not affect calls in progress, but could cause a call<br />

origination to abort or a user will not get dial tone when going<br />

off-hook.<br />

2. If the test passes and the alarm does not resolve, retest with<br />

test tone-clock location long clear.<br />

3. If the test passes, the repair process is completed. If the test fails,<br />

replace the circuit pack at the customer’s convenience.<br />

PASS TDM bus Clock Circuit Status is sane. There are no clock-detection<br />

circuit problems on the Tone-Clock circuit.<br />

1616 Maintenance <strong>Alarms</strong> for <strong>Avaya</strong> Communication Manager, Media Gateways and <strong>Server</strong>s<br />

3 of 3

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!