Communication Manager Maintenance Object Repair Procedures<br />

Error log entries and recommended actions<br />

Table 338: SVC-SLOT Error Log Entries<br />

Error<br />

Type<br />

Aux<br />

Data<br />

Associated Test Alarm<br />

Level<br />

On/Off<br />

Board<br />

600 (a) None MIN ON<br />

Recommended<br />

Action<br />

Note:<br />

a. Ian invalid circuit pack was inserted in slot 00, the SERVICE slot, of a J58890BB port<br />

carrier. See the list of valid circuit packs.<br />

1. To see the invalid circuit pack’s TN code, enter list configuration board<br />

location where location specifies the cabinet number, the carrier letter, and the slot<br />

number (always 00) of the alarmed circuit pack.<br />

2. To retire the alarm, remove the invalid circuit pack.<br />