Communication Manager Maintenance Object Repair Procedures<br />

For EI-to-EI fiber links, this test is run on both EI circuit pack endpoints of the fiber link. This test<br />

runs on EXP-INTF (Expansion Interface Circuit Pack) and FIBER-LK (Fiber Link).<br />

Table 469: Expansion Interface Fiber Out-of-Frame Query Test (#238) 1 of 2<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

ABORT Internal system error.<br />

1. Retry the test at 1-minute intervals up to 5 times.<br />

1033 ABORT The EI circuit pack does not have a fiber link administered to it. There is not<br />

sufficient data to run test. Because test fiber-link was run, the<br />

expansion interface should be administered on a fiber link, therefore this<br />

must be a software problem.<br />

2000 ABORT Response to the test was not received within the allowed time.<br />

1. Retry the test at 1-minute intervals up to 5 times.<br />

2100 ABORT System resources required to run this test are not available.<br />

1. Retry the test at 1-minute intervals up to 5 times.<br />

2500 ABORT Internal system error<br />

1. Retry the test at 1-minute intervals up to 5 times.<br />

FAIL The EI circuit pack could not detect the framing signal. Several fail codes<br />

may be returned depending on which endpoint cannot frame up. Error<br />

codes 2326, 2327, and 2328 denote Endpoint 1, Endpoint 2, and both<br />

endpoints, respectively.<br />

1. Clear any SYNC and TDM-CLK errors listed in the error log.<br />

2. Run test board location for each EI board on this fiber link and<br />

follow the appropriate repair sequence for any failing tests.<br />

3. If the EI circuit pack that is failing Test #238 is in the PN, and the red<br />

LEDs are ON for a large number of circuit packs, then reseat any<br />

Tone-Clock circuit packs in the PN. See Replacing the IPSI or<br />

Tone-Clock Circuit Pack instructions.<br />

4. Enter display errors and follow the associated repair procedures<br />

for any SNC-BD (Switch Node Clock Circuit Pack) (if applicable to this<br />

fiber link configuration) or TDM-BUS (TDM Bus) errors.<br />

5. Perform the Fiber link fault isolation procedures described in Chapter<br />

4: General troubleshooting in Maintenance Procedures (03-300432).<br />

6. If the test continues to abort, follow normal escalation procedures.<br />