EXP-INTF (Expansion Interface Circuit Pack)<br />

MO Name in Log Alarm<br />

Level<br />

EXP-INTF MAJ<br />

MIN<br />

WRN<br />

EXP-INTF (Expansion Interface Circuit Pack)<br />

! WARNING:<br />

WARNING: If the Expansion Interface (EI) circuit pack that is being investigated is associated<br />

with a Survivable Remote EPN (SREPN), every LAPD EI link problem must be<br />

cleared, and the SREPN slide switch on the TN2301 (located in the SREPN<br />

carrier) must be manually set to the normal position before the SREPN can be<br />

returned to normal service. See Restoring Normal Service to the SREPN.<br />

Refer also to <strong>Avaya</strong> MultiVantage Solutions Installation and Maintenance for Survivable Remote<br />

EPN, 555-233-121.<br />

Following this introductory description of the Expansion Interface (EI) circuit pack are sections<br />

on the following topics:<br />

● EI In-Service Mechanism<br />

● Survivable Remote EPN<br />

● LEDs<br />

● EI and Tone-Clock Interactions<br />

● Replacing an EI Circuit Pack—Unduplicated PNC<br />

● Replacing an EI Circuit Pack— Duplicated PNC<br />

● Expansion Interface Manual Loopback Procedure<br />

The TN570 or the TN776 Expansion Interface (EI) circuit pack provides a TDM- and packet<br />

bus-to-fiber interface for the communication of signaling information, circuit-switched<br />

connections, and packet-switched connections between endpoints residing in separate PNs. EI<br />

circuit packs are connected via optical fiber links. An EI can be connected to:<br />

● Another EI, in a direct-connect configuration<br />

● A DS1 converter in a DS1 converter complex, used to remote a PN<br />

● A Switch Node Interface (SNI), in a center stage switch (CSS) configuration<br />

● A survivable remote EPN (SREPN)<br />

Initial Command to Run Full Name of MO<br />

test board location Expansion Interface<br />

circuit pack<br />

Communication Manager Release 5.0 Issue 4 January 2008 799