Expansion Interface Lightwave Transceiver Looparound Test (#242)<br />

Table 472: Expansion Interface Lightwave Transceiver Looparound Test (#242) 4 of 5<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

1 FAIL The test did not detect the test tone through the looparound connection.<br />

The packet portion of this test was not run since the circuit portion failed.<br />

1. Test the active Tone-Clock on the PN that contains the defective EI<br />

circuit pack to verify that dial tone is being supplied.<br />

2. If the Tone-Clock is healthy, enter test board location long<br />

on the EI circuit pack.<br />

3. If this test continues to fail, replace the EI circuit pack or transceiver.<br />

Then enter test board location long on the new EI circuit<br />

pack.<br />

2 FAIL The test tone was transmitted and detected correctly, but the correct data<br />

packet was not detected by the TN1655 Packet Interface circuit pack.<br />

1. Test the TN1655 Packet Interface circuit pack to verify that it is<br />

functioning properly. If any tests fail, investigate those tests and<br />

repair the Packet Interface circuit pack.<br />

2. If the Packet Interface circuit pack checks out OK, enter display<br />

errors and display alarms and resolve any SNI-BD and<br />

FIBER-LK alarms or errors (Center Stage Switch only) and DS1C-BD<br />

alarms or errors (if present).<br />

3. Enter test board location long on the EI board.<br />

4. If Test #242 continues to fail, replace the EI board. Then enter test<br />

board location long for the new EI board.<br />

5. If Test #242 continues to fail, replace the lightwave transceiver, reset<br />

the circuit pack and enter test board location long on the EI<br />

circuit pack.<br />

4 of 5<br />

Communication Manager Release 5.0 Issue 4 January 2008 1681