Communication Manager Maintenance Object Repair Procedures<br />

BRI-SET, Various Adjuncts<br />

WARNING: Information<br />

MO Name in Log Alarm<br />

Level<br />

BRI-SET WRN 1<br />

Initial Command to Run Full Name of MO<br />

test station extension l ISDN-BRI Set<br />

BRI-DAT WRN1 test data-module extension l ISDN-BRI Data Module<br />

ASAI-ADJ MAJ1 test station extension<br />

test data-module extension<br />

WRN 2<br />

ATT-ADJ MAJ1<br />

WRN2<br />

LGATE-AJ MAJ1<br />

WRN2<br />

ATTE-AJ MAJ1<br />

WRN2<br />

test data-module extension<br />

ASAI-Adjunct<br />

test station extension <strong>Avaya</strong>-Adjunct<br />

test station extension Ethernet ASAI-Adjunct<br />

test station extension Ethernet <strong>Avaya</strong>-Adjunct<br />

1. The alarm level for ASAI and <strong>Avaya</strong> adjuncts may be administered using set options. The alarm level can<br />

be set independently for on- and off-board alarms to WARNING, MINOR, or MAJOR for every ASAI and<br />

<strong>Avaya</strong> adjunct in the system.<br />

2. Alarming for an ASAI and <strong>Avaya</strong> adjuncts is disabled if the adjunct asks the switch to suspend<br />

maintenance. When this occurs, an error and a WARNING alarm are logged against the endpoint. Busying<br />

out and releasing the ASAI station or ADDLE station will clear the alarm.<br />

! WARNING:<br />

for isolating and resolving packet bus faults is included in Isolating<br />

and repairing packet-bus faults in Maintenance Procedures (03-300432). The<br />

Troubleshooting Packet Bus Problems flowchart, along with the other information<br />

presented in the chapter, can help resolve problems that involve more than a<br />

single station or circuit pack.<br />

! WARNING:<br />

WARNING: If a significant packet bus failure occurs, errors and alarms may not be logged as<br />

expected for BRI-PORT/ABRI-POR/ATT-PORT/ LGATE-PT/ ATTE-PT.<br />

Conditions under which this occurs are detailed in the Isolating and repairing<br />

packet-bus faults in Maintenance Procedures (03-300432).<br />

The TN2208 ESAI MFB provides the system with an Ethernet interface to Adjunct-Switch<br />

Application Interface (ASAI) and <strong>Avaya</strong> adjuncts (for example, CONVERSANT ® Voice System).<br />

This circuit pack contains 8 ports of line circuit interface, each of which operates with two<br />

B-Channels (referred to as B1 and B2 throughout this section) and one D-Channel. In this<br />

598 Maintenance <strong>Alarms</strong> for <strong>Avaya</strong> Communication Manager, Media Gateways and <strong>Server</strong>s

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!