09.12.2012 Views

Server Alarms - Avaya Support

Server Alarms - Avaya Support

Server Alarms - Avaya Support

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Communication Manager Maintenance Object Repair Procedures<br />

Table 470: Expansion Interface Local Looparound Test (#240) 2 of 4<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

2 ABORT Could not allocate time slot on TDM Bus B. Loopback passed on TDM<br />

Bus A.<br />

1. If there is no reason to doubt that the EI circuit pack can transfer<br />

data to or from a TDM Bus, then since the test passed on one bus,<br />

assume that the test passes on the other bus.<br />

2. If this test continues to abort with the same error, rerun test at<br />

1-minute intervals up to 3 times.<br />

3. If the test still does not pass on the other TDM Bus, follow the<br />

procedure for ABORT Error Code 3.<br />

3 ABORT The system could not allocate time slots for the test on either TDM Bus.<br />

The system may be under heavy traffic conditions or it may have time<br />

slots out of service due to TDM-BUS errors.<br />

1. If the system has no TDM-BUS errors and is not handling heavy<br />

traffic, retry the command at 1-minute intervals up to 3 times.<br />

1003 ABORT The system could not allocate a tone receiver for the test. The system<br />

may be oversized for the number of Tone Detectors present, or some<br />

Tone Detectors may be out of service.<br />

1. Enter list measurements tone-receiver to see information<br />

regarding the system’s tone receivers.<br />

2. Resolve any TTR-LEV (TTR Level) errors.<br />

3. Resolve any TONE-PT (Tone Generator) errors.<br />

4. Retry the command at 1-minute intervals up to 5 times.<br />

1031 ABORT A query of the EI circuit pack aborted. The purpose of this query was to<br />

see if the EI circuit pack could detect the framing signal.<br />

1. If Test #238 aborted, follow the procedure associated with this abort<br />

code.<br />

2. If Test #238 did not abort, rerun Test #240 at 1-minute intervals up to<br />

3 times.<br />

1032 ABORT The EI cannot detect the framing signal and cannot run the test.<br />

1. Refer to the errors for Expansion Interface Fiber Out-of-Frame<br />

Query Test (#238) to determine why the EI circuit pack is out of<br />

frame.<br />

1668 Maintenance <strong>Alarms</strong> for <strong>Avaya</strong> Communication Manager, Media Gateways and <strong>Server</strong>s<br />

2 of 4