09.12.2012 Views

Server Alarms - Avaya Support

Server Alarms - Avaya Support

Server Alarms - Avaya Support

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Communication Manager Maintenance Object Repair Procedures<br />

For IPMEDPRO: Use the change ip-interface screen to disable the Media Processor’s IP<br />

interface before performing this procedure.<br />

For the Tone-Clock circuit packs, DS1 Interface circuit packs, and DS1 Interface Media<br />

Modules, this test is executed as part of the long test sequence.<br />

This test is run on the following maintenance objects:<br />

● DS1-BD (DS1 Interface Circuit Pack)<br />

● MAPD-BD (MAPD Interface Circuit Pack)<br />

● MEDPRO (Media Processor MAPD Circuit Pack)<br />

● MG-ANA (Analog Media Module)<br />

● MG-DS1 (DS1 Interface Media Module)<br />

● MMI-BD (Multimedia Interface Circuit Pack)<br />

● RC-BD (Radio Controller Board)<br />

● TDM-CLK (TDM Bus Clock)<br />

● TONE-BD (Tone-Clock Circuit Pack)<br />

● TONE-PT (Tone Generator)<br />

● UDS1-BD (UDS1 Interface Circuit Pack)<br />

● XXX-BD (Common Port Circuit Pack/Media Module)<br />

Table 400: SAKI Sanity Test (#53) 1 of 2<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

ABORT System resources required for this test are not available.<br />

1. Retry the command at 1-minute intervals up to 5 times.<br />

1005 ABORT This error applies only to DS1 interface circuit packs and DS1 media<br />

modules. It means the DS1 interface circuit pack or media module is<br />

providing timing for the system and, therefore, it cannot be reset without<br />

causing major system disruptions. If this is not a media gateway<br />

system, go to Step 1. If this is a media gateway system, go to Step 2.<br />

1. If the circuit pack needs to be reset, set synchronization to another<br />

DS1 interface circuit pack or the Tone-Clock circuit pack and try the<br />

command again. See SYNC (Port Network Synchronization).<br />

2. If the DS1 Media Module needs to be reset, set the synchronization<br />

timing source to another DS1 interface Media Module located in the<br />

same media gateway and retest. See Setting G700 synchronization<br />

in Maintenance Procedures (03-300432).<br />

1518 Maintenance <strong>Alarms</strong> for <strong>Avaya</strong> Communication Manager, Media Gateways and <strong>Server</strong>s<br />

1 of 2