09.12.2012 Views

Server Alarms - Avaya Support

Server Alarms - Avaya Support

Server Alarms - Avaya Support

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Communication Manager Maintenance Object Repair Procedures<br />

3. A particular Tone-Clock circuit pack can be made active by entering set tone-clock<br />

location [override]. If the Tone-Clock to be made active is less healthy than the<br />

currently active one, no interchange will occur unless the override option is specified;<br />

without it a message will inform the user that it is required.<br />

Once a Tone-Clock circuit pack is made active by the set tone-clock location<br />

command, it will stay active until either the set tone-clock location command is<br />

entered again to make the other circuit pack active, or until a fault occurs in the active<br />

Tone-Clock circuit pack, which causes the system to interchange Tone-Clocks.<br />

S8700 | S8710 | S8720 | S8500<br />

Firmware Instigated Tone-Clock Interchanges<br />

Firmware-initiated Tone-Clock interchanges occur when the auto clock switching option is<br />

enabled, and the TN2312 IPSI circuit pack firmware detects a loss of clock or clock errors. After<br />

detecting a loss of clock/clock errors, and rather than waiting for system software to request a<br />

switch, the IPSI firmware will automatically switch the clock (when auto clock switching is<br />

enabled). The auto clock switching option is disabled during system restarts.<br />

Note: The<br />

Note:<br />

auto clock switching option is required by the IPSI circuit pack since the EAL<br />

connection to the PKT-INT (one of the IPSI circuit packs many functions) is over<br />

the server packet bus which must have a good clock for proper operation.<br />

S8700-series Fiber-PNC<br />

Clock Synchronization<br />

Note:<br />

Note: Stratum-3 clocking is not available for a port network supported by a TN2312<br />

(IPSI) circuit pack, or a port network where the Tone-Clock function is supplied by<br />

a TN2182.<br />

This section discusses synchronization with a Stratum-3 or -4 clocking device.<br />

1354 Maintenance <strong>Alarms</strong> for <strong>Avaya</strong> Communication Manager, Media Gateways and <strong>Server</strong>s

Hooray! Your file is uploaded and ready to be published.

Saved successfully!