EXP-INTF (Expansion Interface Circuit Pack)<br />

o. Error Type 3073: Perform the following steps for Error Type 3073:<br />

1. Execute display errors and resolve any errors on the following: PKT-BUS, PKT-INT,<br />

BRI-BD, BRI-PT, BRI-SET/ASAI, UDS1-BD.<br />

2. Enter test board location r 3 for this circuit pack. If this error continues to appear,<br />

replace the EI circuit pack.<br />

p. Error Types 3074 and 3075: failures of the EI circuit pack Packet Path test. The packet<br />

path test exercises circuitry on the EI circuit pack, the neighbor EI or SNI circuit pack, and<br />

any intervening DS1 converter circuit packs (if the PN is remoted).<br />

1. Certain packet bus faults can cause these errors without the EI being defective. Check if<br />

PKT-BUS errors are also present. If they are, see PKT-INT (Packet Interface) and<br />

Isolating and repairing packet-bus faults in Maintenance Procedures (03-300432) to<br />

diagnose the problem.<br />

2. If Error Type 3075 is present without Error Type 3074, replace the EI circuit pack.<br />

3. If Error Type 3074 exists with or without 3075, run test board location on the EI,<br />

and follow the repair procedures for any test that does not pass.<br />

4. If PKT-BUS errors are absent and replacing the EI does not resolve the problem, there<br />

may be a packet bus fault. See Isolating and repairing packet-bus faults in Maintenance<br />

Procedures (03-300432).<br />

q. Error Type 3330: failure of a diagnostic component on the EI circuit pack. The failed<br />

component will not impair service, but it may leave the EI circuit pack in a state where the EI<br />

circuit pack cannot detect errors.<br />

1. Replace the EI circuit pack at a time when it is most convenient for the customer (this<br />

may cause service outages).<br />

r. Error Type 3585: the EI circuit pack experienced a series of very short out-of-frame<br />

conditions within several minutes. This may indicate transmission difficulties over the fiber<br />

link. If this condition ceases, the warning alarm should be resolved within 15 minutes.<br />

1. Enter display errors and resolve any SNC-BD (Switch Node Clock Circuit Pack),<br />

TDM-BUS (TDM Bus), TDM-CLK (TDM Bus Clock) or SYNC (Port Network<br />

Synchronization) errors.<br />

s. Perform the Fiber link fault isolation procedures described in Chapter 4: General<br />

troubleshooting of Maintenance Procedures (03-300432).<br />

1. If the alarm is not resolved within the next 15 minutes, replace the lightwave transceiver<br />

on the EI circuit pack reporting the problem and on the connected EI circuit pack, SNI<br />

circuit pack, or DS1 converter circuit pack.<br />

2. If the alarm is not resolved within the next 15 minutes, replace the EI circuit pack<br />

reporting the alarm.<br />

3. If the alarm is not resolved within the next 15 minutes, replace the connected EI circuit<br />

pack, SNI circuit pack, or DS1 converter circuit pack.<br />

t. Error Type 3841: the EI has reported a loss of lock with the backplane system clock.<br />

Communication Manager Release 5.0 Issue 4 January 2008 821