Expansion Interface Control Channel Test (#316)<br />

If the circuit pack is a standby ATM-EI or EI (amber LED off), this test queries the circuit pack for<br />

its type and vintage information. This test runs on ATM-EI (Expansion Interface Circuit Pack)<br />

and EXP-INTF (Expansion Interface Circuit Pack).<br />

Table 488: Expansion Interface Control Channel Test (#316) 1 of 2<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

1030 ABORT The test is not being executed on the active PE in a duplex system.<br />

1335 ABORT The PKTINT is on the standby SPE<br />

2000 ABORT Response to the test was not received within the allowed time.<br />

1. Retry the command at 1-minute intervals up to 3 times.<br />

2100 ABORT Could not allocate the necessary system resources to run this test.<br />

1. Retry the command at 1-minute intervals up to 3 times.<br />

2500 ABORT Internal system error<br />

1. Retry the command at 1-minute intervals up to 3 times.<br />

FAIL The ATM circuit pack responded incorrectly, or a PN’s active ATM-EI or<br />

EI circuit pack could not communicate with the PN’s circuit packs.<br />

1. If the PN’s active ATM-EI or EI circuit pack is failing and duplicated<br />

PNC is enabled:<br />

a. Enter reset PNC interchange to switch to the standby PNC.<br />

b. Repeat the short test sequence.<br />

c. If test continues to fail, enter reset board location to reset<br />

the circuit pack.<br />

2. If the PN’s unduplicated ATM-EI or EI circuit pack is failing:<br />

a. Enter display errors and display alarms, and follow the<br />

associated repair procedures for TDM-CLK (TDM Bus Clock),<br />

TONE-BD (Tone-Clock Circuit Pack), or SYNC (Port Network<br />

Synchronization) alarms/errors.<br />

b. Repeat the short test sequence.<br />

c. If test continues to fail, replace the circuit pack or transceiver.<br />

PASS The circuit pack responded correctly to the test. Communication from<br />

software to the ATM-EI or EI circuit pack is functioning.<br />

1. Refer to other ATM-EI or EI circuit pack tests if the link is not<br />

functioning correctly.<br />

1 of 2<br />

Communication Manager Release 5.0 Issue 4 January 2008 1711

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!