ANL-LINE (8-Port Analog Line)<br />

a low ringer impedance. Call the terminal equipment and verify that the terminal rings. If the<br />

terminal doesn’t ring, replace it. Otherwise, enter test port location, and follow the<br />

procedure for ONS Ringer Application Test (#48).<br />

Aux Data 40977: no terminal equipment was connected when ringing was attempted. Run<br />

test port location, and follow the procedure for the results of ONS Ringer Application<br />

Test (#48).<br />

c. Error Type 15: software audit error, does not indicate any hardware malfunction. Run the<br />

short test sequence, and investigate errors (if any).<br />

d. Error Type 130: the circuit pack was removed or has been insane for more than 11 minutes.<br />

To clear the error, reinsert or replace the circuit pack.<br />

e. Error Type 257: Associated Test #48 may cause some terminal equipment to ring briefly<br />

during daily maintenance. If this ringing is disturbing the customer or the terminal<br />

equipment, it should be disabled via change station extension. However, on some<br />

releases of the software, this will disable Tests #6, 47, and 35 as well as Test #48.<br />

f. Error Type 769: Associated Test #47 may cause a false alarm when the port is connected<br />

to off-premises equipment, some non-voice terminal equipment, and some loop equipment.<br />

If this causes a false alarm, use change station, and change the Tests field to n to<br />

disable the test.<br />

g. Error Types 1281 and 1793: See XXX-BD (Common Port Circuit Pack/Media Module).<br />

Demand test descriptions and error codes<br />

Investigate tests in the order presented. By clearing errors associated with the first test, errors<br />

generated from other tests may also be cleared. Click on the link to see the full description of<br />

the test, error codes, and recommended actions.<br />

Order of Investigation Short Test Sequence Long Test Sequence D/ND 1<br />

Port Diagnostic Test (#35) X X ND<br />

ONS Ringer Application Test (#48) X X ND<br />

NPE Crosstalk Test (#6) X ND<br />

Looparound and Conference Test (#47) X ND<br />

Port Audit And Update Test (#36)<br />

1. D = Destructive; ND = Nondestructive<br />

X X ND<br />

Communication Manager Release 5.0 Issue 4 January 2008 463