DSP Port TDM Looparound Test (#1380)<br />

(440Hz) onto a timeslot. The timeslot is listened to by the Media Processor board. The tone is<br />

routed through the board’s DSP farm, where it may undergo transcoding to G.723, etc. The tone<br />

is looped back at the Network interface and back through the board where it is converted back<br />

into standard PCM. The tone is placed onto a TDM timeslot and detected by a tone detector<br />

port. The test passes if 440Hz is reported by the tone detector<br />

This test runs on MEDPROPT (MEDPRO DSP PORT).<br />

Table 617: DSP Port TDM Looparound Test (#1380) 1 of 2<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

1002 ABORT The system could not allocate time slots for the test. The system may be<br />

under heavy traffic conditions, or it may have time slots out-of-service due<br />

to TDM-BUS errors. A system is considered under heavy traffic when the<br />

Call Processing Occupancy is greater than 50% or when the System<br />

Management and the Call Processing Occupancies together exceed<br />

65%.<br />

1. Enter status health to view the occupancy measurements.<br />

2. Enter display errors and resolve any TDM-BUS (TDM Bus)<br />

errors.<br />

3. If the system has no TDM-BUS errors and is not handling heavy<br />

traffic, retry the command at 1-minute intervals up to 5 times.<br />

1003 ABORT The system could not allocate a tone receiver for the test. The system<br />

may be oversized for the number of Tone Detectors present, or some<br />

Tone Detectors may be out of service.<br />

1. Enter list measurements tone-receiver to see information<br />

regarding the system’s tone receivers.<br />

2. Resolve any TTR-LEV (TTR Level) errors.<br />

3. Resolve any TONE-PT (Tone Generator) errors.<br />

4. Retry the command at 1-minute intervals up to 5 times.<br />

1014 ABORT Board not inserted.<br />

2000<br />

2100<br />

2500<br />

ABORT Response to the test was not received in the allowed time.<br />

Could not allocate the necessary system resources to run this test.<br />

Internal system error.<br />

1. Retry the command at 1-minute intervals up to 3 times.<br />

2801 ABORT The TN802B/TN2302 Media Processor board has not been administered<br />

on the ip-interfaces screen.<br />

1 of 2<br />

Communication Manager Release 5.0 Issue 4 January 2008 2001