Communication Manager Maintenance Object Repair Procedures<br />

Table 392: Tone Detection Verification Test (#42) 3 of 3<br />

Error<br />

Code<br />

110-122<br />

130<br />

Test<br />

Result<br />

FAIL A Tone Level Test failed.<br />

Forward/backward MFC signals not correctly generated/detected.<br />

1. Run the short test sequence with test port location<br />

2. If the problem persists, the system is still operating properly but<br />

capacity will be reduced. To restore performance to normal,<br />

replace the circuit pack containing the defective port. See<br />

TONE-BD (Tone-Clock Circuit Pack) for the procedures to<br />

replace a Tone-Clock circuit pack.<br />

1022 FAIL Invalid tone detector circuit pack. Tone detection for the system is<br />

administered as wideband but the tone detector circuit pack is invalid.<br />

Ports on invalid types of tone detector circuit packs are taken out of<br />

service since they cannot provide the administered function.<br />

1. Change the tone-detection mode administered on the<br />

system-parameters country-options screen, or remove every<br />

tone detector circuit pack from the system except the following:<br />

TN2182, TN2312, TN8412, TN420C or later, TN744C or later.<br />

2. Retry the command.<br />

PASS Tone detection verification is successful. The port is able to detect and<br />

generate every necessary tone.<br />

Tone Detector Audit/Update Test (#43)<br />

The Tone Detector Audit/Update Test performs a sanity audit on the following port types:<br />

● CLSFY-PT (Call Classifier Port)<br />

Description / Recommendation<br />

● DTMR-PT (Dual-Tone Multifrequency Receiver Port)<br />

● ETR-PT (Enhanced Tone Receiver Port)<br />

● GPTD-PT (General-Purpose Tone Detector Port)<br />

● TONE-BD (Tone-Clock Circuit Pack)<br />

1500 Maintenance <strong>Alarms</strong> for <strong>Avaya</strong> Communication Manager, Media Gateways and <strong>Server</strong>s<br />