Hybrid Line Local Digital Looparound Test (#58)<br />

Hybrid Line Local Digital Looparound Test (#58)<br />

This test checks the control channel between the server and the port’s digital circuitry. The<br />

server sends data to the on-board microprocessor and compares the data echoed back. This<br />

test is run on HYB-LINE (Hybrid Line).<br />

Table 403: Hybrid Line Local Digital Looparound Test (#58) 1 of 2<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

ABORT Internal system error.<br />

1. Retry the command at 1-minute intervals up to 5 times.<br />

1000 ABORT System resources required to run this test are not available. The port may<br />

be busy with a valid call.<br />

1. Enter display port location to determine the station extension<br />

number of the port.<br />

2. Enter status station to determine the service state of the port. If<br />

the port is in use, wait until it is idle before testing.<br />

3. Retry the command at 1-minute intervals up to 5 times.<br />

1004 ABORT The port was seized by a valid call during the test.<br />

1. Enter display port location to determine the station extension<br />

number of the port.<br />

2. Enter status station to determine the service state of the port. If<br />

the port is in use, wait until it is idle before testing.<br />

3. Retry the command at 1-minute intervals up to 5 times.<br />

2000 ABORT Response to the test was not received within the allowed time.<br />

1. Retry the command at 1-minute intervals up to 5 times.<br />

1 of 2<br />

Communication Manager Release 5.0 Issue 4 January 2008 1525