Table 388: Port Diagnostic Test (#35) 3 of 6<br />

Error<br />

Code<br />

Test<br />

Result<br />

Description / Recommendation<br />

Port Diagnostic Test (#35)<br />

1004 ABORT ALARM-PT: The port received an EXT-DEV failure during the test.<br />

1. Enter test external-device-alarm port location to<br />

determine whether the port is reporting an EXT-DEV failure.<br />

2. If the port has no EXT-DEV failures, retry the command at<br />

1-minute intervals up to 5 times.<br />

ANL-16-L, ANL-LINE, AN-LN-PT, DID-TRK, MET-LINE, RANL-STA:<br />

The port was seized by a valid call during the test.<br />

1. Enter display port location to determine the station<br />

extension, attendant number, or trunk group/member number of<br />

the port.<br />

2. Enter status station, status attendant, or status<br />

trunk to determine the service state of the port. If the port is in<br />

use, wait until it is idle before testing. Attendants are always in use<br />

(off-hook) if the handset is plugged in and the port is not busied<br />

out.<br />

3. Retry the command at 1-minute intervals up to 5 times.<br />

1005 ABORT The test is not applicable for this type of port. This error can be ignored.<br />

1018 ABORT DID-TRK: The test has been disabled by administration.<br />

1. To enable the test, enter change trunk-group x, where x is<br />

the trunk group number. Change the Maintenance Tests field to y.<br />

2. Retry the command.<br />

All other Maintenance Objects: The test has been disabled by<br />

administration. Determine why the Maintenance Tests field on the<br />

station form was set to n on this station. It may be due to the ONS<br />

Ringer Application Test #48, which can be customer or terminal<br />

disturbing.<br />

1. To enable the test for the particular analog station being tested,<br />

enter change station extension and set the Maintenance<br />

Tests field to y.<br />

2. Retry the command.<br />

3 of 6<br />